2 PREPARATION FOR MEASUREMENT
2.3 Power Switch Key ON
1 Conrm the instrument is leveled.
2 Press the power key..
Conrm the battery power remaining display. Replace with charged battery or charge when battery
level is low or indicates “Battery empty”. see Section 2.4“Battery Power Remaining Display” .
Contrast adjustment
You can conrm prism constant value (PSM), non-prism constant value (NPM), atmospheric
correction value (PPM) and you can also adjust the contrast of the display when the instrument is
turned on.
To display this screen, see Chapter 16 “SELECTING MODE” .
This enables you to adjust the brightness by pressing the [F1](
) or [F2](
) key.
To memorize the setting value after powering off, press [F4](ENTER) key.
Press the power key
TOPCON GPT-2000
V : 90°10'20"
HR: 0°00'00"
0SET HOLD HSET P1
Battery Power Remaining Display
CONTRAST ADJUSTMENT
PSM: 0.0 PPM 0.0
NPM: 0.0
- - - ENTER